Based on Microfluidic technology, LOCMEDT reagent discs are de-signed to perform all the steps required to convert 3 drops of blood sample to several accurate results.
lt is a 8 cm diameters rotor with 30 cuvettes. The diluent and lyo-philized reagent beads are pre-installed into the disc.
Microfluidic Technology
Built-in Lyophilized Reagent Beads
Multi-parameter Combination Panels
Built-in Diluent
Features of Noahcali-100 Automatic Veterinary Biochemistry Analyzer Reagent Discs
Multi-Parameter Combination
20 different panels with more than 50 parameters.
Unique Built-in Reagent Technology
Built-in lyophilized reagent beads and diluent in panels.
Single Use
One panel used for single run of sample.
No Cross Contamination
Individual channel design in panel to avoid contamination.
Pre-installed QR Code
QR Code contains the disc identification code, lot, expiry date and calibration information.
Longer Shelf Life
Unique lypholization process, one and half year shelf life under refrigeration at 2~8℃
Specification of Noahcali-100 Automatic Biochemistry Analyzer Reagent Discs
Full Biochemistry Panel 43
ALB
ALP
ALT
AMY
AST
BUN
CHE
CK
CRE
DBIL
FRUC
GGT
GLU
HDL-C
LAC
LDH
LPS
PHOS
TBA
TBIL
TC
tCO2
TG
TP
UA
α-HBDH
Ca
Na+
K+
Cl-
Mg2+
GLOB*
A/G*
AG*
BUN/CRE*
AST/ALT*
α-HBDH/LDH*
IBIL*
LDL-C*
Osm*
Ca*P*
C-Ca*
Na+/K+*
Comprehensive Diagnostic Panel 26
TP
ALB
TBIL
ALT
AST
BUN
CRE
TBA
GLU
TG
TC
Ca
GGT
LDH
PHOS
CK
UA
LPS
AMY
ALP
GLOB*
A/G*
BUN/CRE*
Ca*P*
AST/ALT*
C-Ca*
Health Check Panel 16
ALB
ALP
ALT
AMY
BUN
CK
CRE
GLU
PHOS
TBIL
TC
TP
Ca
GLOB*
A/G*
BUN/CRE*
Health Check Plus Panel 20
ALB
ALT
AMY
ALP
Ca
CRE
GGT
GLU
K+
Na+
PHOS
TBIL
TC
TP
tCO2
BUN
GLOB*
A/G*
BUN/CRE*
Na+/K+*
Large Animal Panel 21
ALB
ALP
AST
BUN
Ca
CK
CRE
GGT
GLU
LDH
Mg2+
Na+
K+
PHOS
TBIL
TG
TP
GLOB*
A/G*
BUN/CRE*
Na+/K+*
Preanesthetic Panel 14
TP
CK
ALT
AST
BUN
CRE
GLU
LDH
ALP
ALB
BUN/CRE*
AST/ALT*
GLOB*
A/G*
Feline Inflammation Panel 13
fSAA
LPS
AMY
ALB
TP
BUN
CRE
TBA
GGT
ALP
A/G*
GLOB*
BUN/CRE*
Feline Inflammation Plus Panel 16
fSAA
LPS
AMY
ALB
TP
BUN
CRE
TBA
GGT
ALP
ALT
AST
A/G*
GLOB*
BUN/CRE*
AST/ALT*
Canine Inflammation Panel 10
cCRP
LPS
AMY
TP
BUN
CRE
ALB
A/G*
GLOB*
BUN/CRE*
Canine Inflammation Plus Panel 13
cCRP
LPS
AMY
TP
BUN
CRE
ALB
ALT
AST
A/G*
GLOB*
BUN/CRE*
AST/ALT*
Coagulation Panel 4
TT
FIB
PT
APTT
Liver and Kidney Function Panel 14
TP
ALB
TBIL
ALT
AST
BUN
CRE
GLU
GGT
ALP
GLOB*
A/G*
AST/ALT*
BUN/CRE*
Liver Function Panel 13
TP
ALB
TBIL
TBA
ALT
AST
UA
TC
GGT
ALP
GLOB*
A/G*
AST/ALT*
Kidney Function Panel 9
ALB
PHOS
BUN
CRE
UA
Ca
K+
tCO2
BUN/CRE*
Critical Care Panel 13
ALT
AMY
CHE
BUN
CRE
NH₃
GLU
Na+
K+
tCO2
Cl-
BUN/CRE*
Na+/K+*
Cardiac Function Auxiliary Check Panel 12
ALB
AST
CK
LAC
LDH
TC
TG
TP
α-HBDH
GLOB*
A/G*
α-HBDH/LDH*
Diabetes Panel 10
ALT
AMY
AST
FRUC
GLU
LAC
LPS
TC
TG
AST/ALT*
Diabetes & Comprehensive Diagnostic Panel 20
ALB
ALT
ALP
AST
BUN
CRE
FRUC
GLU
TBIL
TC
TG
TP
Na+
K+
Cl-
GLOB*
A/G*
BUN/CRE*
AST/ALT*
Na+/K+*
Avian & Reptilian Panel 16
ALB
AST
CK
GLU
PHOS
TBA
TP
UA
Ca
Na+
K+
Cl-
GLOB*
A/G*
Ca*P*
Na+/K+*
Blood Gas & Electrolytes Panel 17
BUN
CRE
GLU
LAC
pH
PHOS
tCO2
Ca
Na+
K+
Cl-
Mg2+
AG*
BUN/CRE*
Osm*
Ca*P*
Na+/K+*
FAQ
Q1: What types of samples can be used with Noahcali-100 Clinical Chemistry Analyzer?
The sample should be lithium-heparin whole blood, lithium-heparin plasma, or serum. Do not use EDTA as an anti-coagulant.
Q2: What is the Noahcali-100 Veterinary Biochemistry Analyzer sample volume required?
Usually 90-120μL for a test(about 3 drops), but for Critical Care Panel 13 only accept 120μL plasma.
Q3: What is the shelf life of the Noahcali-100 Biochemistry analyzer reagent discs?
The shelf life of the disc can be 18 months and the discs should be stored refrigerated at 2-8°C
Q4: Can expired disc be used in the Noahcali-100 Vet Blood Chemistry Analyzer?
No, the analyzer will cancel the run and display an Error Code message.
Q5: Does the disc require warm-up time before using?
No, the users can use the disc directly from the refrigerator
Q6: How long can the Noahcali-100 biochemistry analyzer reagent disc be used after removing from the foil pouch?
After opening the pouch, the discs should be used in 20 minutes.
Navigation
Tel.: +86 22 5860 1276
Mob.: +86 155 1086 2356
E-mail: shirleyhan@locmedt.com
WhatsApp: 8615510862356
Add.: Floor 4, Building B3, Huaming High-tech Industrial Zone, No.6 Huafeng Road, Dongli District, 300300, Tianjin, China
Contact